TOTALFORCE
I/O Options and Subcase Information Entry Used to request the total force (summation of single-point force of constraint and applied load) output for all subcases or individual subcases, respectively.
Format
TOTALFORCE (format, type, SUBSYS=SUBSYS_ID) = option
Definitions
Argument | Options | Description |
---|---|---|
format | <H3D> Default = H3D |
Note: Other formats are currently not supported and will be
ignored, if specified.
|
type | <SPARSE, ALL> |
|
SUBSYS | <SUBSYS_ID> No default |
ID of the subsystem. When used along a subsystem definition, this option generates an individual result file for each subsystem with results for that subsystem only. For more information, refer to the SET Bulk Data Entry. |
option | <YES, ALL,
NO, NONE,
SID> Default = ALL |
|
Comments
- TOTALFORCE output is the summation of single-point force of constraint (SPCFORCE) and applied load (OLOAD).
- TOTALFORCE output is available only for Linear Static and Nonlinear Static (small and large displacement) analysis types.
- If OLOAD is requested along with TOTALFORCE in the model, OLOAD (SPC) will be activated internally, regardless of the option specified under spc argument in the OLOAD entry.
- The pretension force, specified by the PRETENS entry is also output with the total force output at relevant scalar points (SPOINT). The results at SPOINTs can be viewed in HyperGraph.