PARAM, SPLREFDB
Bulk Data Entry Specifies the reference sound pressure value used to calculate the Sound Pressure Level (SPL) in decibels (dB).
Parameter | Values | Description |
---|---|---|
SPLREFDB | Real > 0.0 Default = 1.0 |
The Sound Pressure Level
(SPL) in decibels can be
calculated using: Where,
|
Comments
- The reference pressure is dependent on the units specified on the UNITS I/O Options Entry. If the units are SI, the value is set as 2.0E-5 Pa. If they are CGS, it is set as 2.0E-4 barye. If they are MPa, it is set as 2.0E-11 MPa. If they are BG or EE, then it is set as 4.17E-7 lbf/ft2. If no UNITS data is present, the default value is 1.0 (exception: see Comment 3 on the PEAKOUT Bulk Data Entry).